Download Specifications of Rheem RTG-53DVN Water Heater for Free or View it Online on All-Guides.com. This version of Rheem RTG-53DVN Manual compatible with such list of devices, as: RTG-53DVN, RTG-53PVN, RTG-53XN, RTGL74DVN, RTGL74XN
- Power Vent Water Heater Menards
- Rheem Power Vent Water Heater Service Manuals
- Rheem Power Vent Water Heater Service Manual Parts
- Rheem Electric Water Heater Manuals
- Direct Vent Water Heater
- Rheem Water Heater Service Manual
Brand: Rheem
For Rheem Stellar, 5 Star Gas and 4 Star Gas storage models the plastic drain near the bottom of the gas water heater will drip water during the heating cycle. It is possible for several litres a day of condensation to discharge from the drain especially in cool conditions. Rheem Water Heater Parts. Do not use this item for any installation or repair of potable water applications. Concentric Vent Kit SP20245.
Category: Water Heater
Type: Specifications
Model: Rheem RTG-53DVN , Rheem RTG-53PVN , Rheem RTG-53XN , Rheem RTG-66DVN , Rheem RTG-66XN , Rheem RTG2-42PVN , Rheem RTGL74DVN , Rheem RTGL74PVN , Rheem RTGL74XN
Pages: 2 (2.62 Mb)
Power Vent Water Heater Menards
Rheem Power Vent Water Heater Service Manuals
Rheem Power Vent Water Heater Service Manual Parts
Rheem Power Vent Water Heater Service Manuals
Rheem Power Vent Water Heater Service Manual Parts
Related Products for Rheem RTG2-42PVN
Related Manuals for Rheem RTG2-42PVN
Rheem RTG2-42PVN: Frequently viewed Manuals
All Brands > Rheem > Checkins > Repair
Most of the problems with a Rheem gas water heater will be related to the FVIR lockout. With most models your first step should be to press the TCO thermal reset button which is located on the front of the combustion door.
Clean the Intake
The next step should be to clean the intake of the water heater. A clogged intake can cause the thermal button to trip. A shop vac with a custom extension or even compressed air can be used to clean the flame arrestor screen (intake). In order to access the intake you will usually need to remove the combustion door.
TRD Glass Vial
Rheem Electric Water Heater Manuals
The above steps will not work for every type of Rheem water heater or for every situation. Many of the Rheem water heaters have a Vial that is located inside of the combustion chamber. If the vial has burst, you will need to wait for a new vial to be shipped. You should also clean out the combustion chamber and pilot assembly. If the pilot is yellow instead of blue there is too much corrosion on the pilot assembly.
Direct Vent Water Heater
Thermocouple or Gas Valve
Rheem Water Heater Service Manual
The next step in troubleshooting should be to test the thermocouple. When attempting to light the water, the flame will usually go out after releasing the control knob when the thermocouple has failed. If the flame continues to burn after releasing while in the PILOT position but shuts down when in the ON position the FVIR may have tripped the system. If the thermocouple shows a good reading you may need to replace the gas valve and FV sensor.